By HPE ProLiant DL360 Gen10 · Published · Updated
If you manage an HPE ProLiant DL360 Gen10 and need to bring its firmware, drivers, or system software up to date, you must choose compatible packages and avoid interrupting production workloads. Installing individual downloads can create dependency problems or leave components at mismatched versions.
This guide explains how to use the HPE Service Pack for ProLiant (SPP), prepare a safe update, run Smart Update Manager, choose between online and offline methods, and verify the result. By the end, you will know which SPP to select, how to update the server, and what to do if a component remains pending or fails.
Use the HPE Service Pack for ProLiant bundles validated firmware, drivers, and system software so a DL360 Gen10 can be updated from a coordinated release rather than through separate downloads.
Use Smart Update Manager to inventory the server, compare installed components with the SPP baseline, and select updates instead of applying every package blindly.
Plan a maintenance window and verify system ROM, iLO, storage, network, and operating-system functionality after the update; firmware changes may require reboots or temporarily interrupt service.
The HPE Service Pack for ProLiant is a tested collection of server firmware, drivers, utilities, and related system software released by Hewlett Packard Enterprise. For a DL360 Gen10, an SPP may contain updates for the system ROM, storage controller, drive firmware, network adapters, power components, and iLO firmware. It can also include operating-system-specific drivers and Smart Update Manager components.
Use an SPP when you want a coordinated release rather than manually selecting every package from HPE Support Center. The SPP gives SUM a known update baseline against which it can compare the server inventory. Individual downloads are more appropriate when you need one emergency fix, a package excluded by policy, or a version that is newer than the current SPP. Do not assume every package applies to every configuration. Let the inventory and compatibility checks determine the applicable updates. Your immediate decision is whether the server needs a broad, coordinated refresh or one narrowly targeted fix.
Record the exact server model, processor and storage configuration, installed operating system, controller models, adapter models, and current firmware versions. Confirm that the target is an HPE ProLiant DL360 Gen10, not a similar-generation system with different support requirements. Capture versions from HPE Integrated Lights-Out 5, the operating system, and any existing management platform such as HPE OneView.
Read the SPP release notes and component documentation before starting. Check supported operating systems, minimum firmware requirements, known issues, required reboots, and whether a component must be updated before another. Some updates require an AC power connection, a functioning iLO connection, or a specific driver state.
Export important iLO, storage controller, BIOS, and operating-system configuration where possible. Confirm that backups are restorable, then schedule a maintenance window with console access and a recovery plan. Stop or migrate workloads before updates that can reboot the host. Now document the current state and approve a window long enough for several reboots.
Sign in to HPE Support Center and search for the DL360 Gen10 or its platform family. Select an SPP release that supports your operating system and intended update path. Review the release date, supported components, release notes, and any advisories before downloading. If the server is managed by HPE OneView, confirm the SPP or firmware bundle is supported by the installed OneView version and its firmware management workflow.
Download the Service Pack for ProLiant ISO or the applicable installation package from the official HPE source. Compare its checksum with the value published by HPE, and keep the file on trusted administrative storage. Do not use a modified image or an unofficial mirror. Mount the ISO on a management workstation or copy it to a controlled repository.
For a local recovery or isolated server, create bootable USB media using a tool approved by your organization. For remote updates, place the ISO or extracted SPP files on a network location reachable by the host or management workstation. Test access before the maintenance window. Your decision now is whether local boot media or a network source gives you the more reliable console and recovery path.
Launch Smart Update Manager (SUM) from the mounted SPP, extracted files, or a supported management workstation. HPE Smart Update Manager can update a local host or discover remote targets, depending on the operating system and network configuration. Provide administrative credentials, confirm the server identity, and ensure the management connection remains available.
Allow SUM to inventory installed firmware, drivers, hardware, and software. Select the SPP as the source baseline, then compare the installed versions with the packages SUM marks as applicable. Read each warning carefully. A component may be current, not applicable, blocked by a dependency, or scheduled for a later reboot. Select only the recommended updates that match your change plan.
Review the proposed firmware and driver updates, reboot requirements, estimated duration, and any components requiring manual action. Confirm that workloads are stopped or migrated and that remote console access works. Start the installation and do not power off the server while firmware is being written. Record the SUM activity and wait for the tool to report completion before deciding whether another reboot is required.
An online update runs SUM while the supported operating system is active. It is convenient for remote administration and can update drivers and firmware without booting from separate media. However, some packages need a reboot, and active applications or loaded drivers can affect the process. Confirm that the operating system, permissions, agents, and network access meet the SPP requirements.
An offline update boots the server from SPP media and runs the update environment outside the installed operating system. This reduces interference from applications and resident drivers and is useful when the operating system is unsupported, unstable, or not yet installed. It still requires console access and may reboot the server more than once.
Choose online mode when the host is supported, remote access is dependable, and downtime is tightly controlled. Choose offline mode when you need a clean environment or cannot trust the operating system. For a production server, the safer method is the one with a tested recovery procedure, reliable console access, and enough downtime. Make that choice before starting the maintenance window.
After SUM finishes and the server has rebooted, sign in to HPE Integrated Lights-Out 5 and compare the system ROM, iLO, storage, and adapter versions with the SPP report. If your environment uses HPE OneView, refresh the server profile or firmware inventory according to its procedures. Do not rely only on a successful installer message.
Check that all physical and logical disks are visible, arrays are healthy, and no controller reports a degraded state. Confirm that network interfaces, link speeds, VLANs, teaming, and driver status are correct. In the operating system, review event logs, services, device status, and application health. Test a representative workload or monitoring check.
Save the SUM report and logs with the change record. Identify packages marked pending, skipped, failed, or requiring a reboot. Some updates complete only after a second restart, while others need manual installation or a prerequisite package. This post-update verification is complete only when versions, hardware health, connectivity, and workloads are normal. Record the final versions and close the change only after those checks pass.
SUM may exclude a package because the operating system, hardware revision, current firmware, or dependency does not match. Read the exclusion reason instead of forcing the installation. Update prerequisites in the order recommended by HPE, or choose a different supported SPP release. A package that is not applicable is not necessarily an error.
If an update fails, keep the server powered and capture the SUM logs, screen messages, and affected component. Check iLO for hardware alerts and use the server console to determine whether the host can boot. Do not repeatedly interrupt a firmware-writing process. If the server is unavailable, follow the component-specific recovery instructions from HPE and use a known-good recovery image only when documented.
Contact HPE support when a critical firmware update leaves the server unable to boot, iLO is inaccessible, storage data is at risk, or the same component fails after following the release notes. Provide the serial number, SPP version, SUM logs, current inventory, console output, and a clear timeline. Stop further changes until support recommends a recovery path. Your immediate action is to preserve evidence and protect data before attempting another update.
Using an SPP safely comes down to selecting a compatible release, letting SUM compare the server with its baseline, and planning enough downtime for reboots. Check the DL360 Gen10 configuration first, validate the download, and choose online or offline mode based on operating-system support and recovery access. Afterward, verify iLO, system ROM, storage, networking, and workloads rather than trusting the installer result alone. With those controls in place, you can keep future updates predictable and repeatable.
Yes. Use SUM to inventory the server and select only applicable updates from the SPP baseline. Review exclusions and dependencies instead of applying packages blindly.
Yes, when the target operating system, network access, credentials, and remote console are supported. Test connectivity and keep local or iLO console access available in case the server reboots.
Use an offline SPP method if the release supports the hardware but not the installed operating system, or select a supported SPP release. Check HPE release notes before proceeding.
Confirm that the hardware is installed, the model is correct, and the package supports the current operating system and firmware. Do not force a package simply because it appears in the SPP.
The time depends on the number of components, reboot requirements, storage configuration, and whether the update is online or offline. Allow extra time for inventory, reboots, verification, and recovery.
Follow the order and prerequisites in the selected SPP release notes and SUM plan. SUM normally evaluates dependencies and recommends an appropriate sequence.
Use iLO console access, record error messages, check hardware alerts, and preserve SUM logs. Avoid repeated power interruptions, then follow HPE recovery guidance or contact HPE support with the collected details.