How to Use HPE ProLiant DL360 Gen10 Diagnostic Tools

Check server health, collect logs, and troubleshoot hardware, storage, firmware, and startup problems

By HPE ProLiant DL360 Gen10 · Published · Updated

When an HPE ProLiant DL360 Gen10 shows a warning, fails to boot, loses a drive, or reports unstable performance, you need more than an operating-system event log. The server includes several diagnostic tools and system logs that reveal hardware status, firmware events, storage conditions, and configuration changes. The challenge is knowing which tool to open first and how to connect evidence from multiple sources.

After reading this guide, you will know how to use HPE Integrated Lights-Out 5 (iLO 5), the Active Health System Log, the Integrated Management Log, UEFI System Utilities, Intelligent Provisioning, and storage diagnostics. You will also be able to collect useful evidence before changing hardware or contacting Hewlett Packard Enterprise support.

Key Takeaways
  • The HPE ProLiant DL360 Gen10 provides several diagnostic paths: iLO 5, the Active Health System Log, the Integrated Management Log, UEFI System Utilities, and Intelligent Provisioning.

  • The Active Health System Log records continuous server hardware and configuration data, making it useful for identifying trends and sharing evidence with HPE Support.

  • Effective troubleshooting starts by correlating symptoms, POST messages, iLO events, IML entries, storage-controller alerts, and operating-system logs instead of relying on a single log source.

Which diagnostic tools are available on the HPE ProLiant DL360 Gen10?

Start by choosing a tool based on the symptom. Remote or intermittent problems usually require iLO and the Active Health System. Startup failures point to POST messages, UEFI System Utilities, or Intelligent Provisioning. Storage alerts require the controller management interface and operating-system evidence.

HPE iLO 5 and the remote management interface

HPE iLO 5 provides out-of-band access even when Windows Server or Linux is unavailable. Its dashboards show component status, temperatures, fans, power supplies, firmware, storage, and recent events. You can also use the remote console to view startup messages and interact with the server without being physically present.

Active Health System Log and Integrated Management Log

The Active Health System Log continuously records hardware and configuration information, while the Integrated Management Log (IML) records server events such as corrected errors, degraded components, and failures. Use AHS for detailed history and IML for a concise event record.

UEFI System Utilities and Intelligent Provisioning

Intelligent Provisioning helps configure hardware and launch maintenance tools. UEFI System Utilities provides firmware settings, boot options, embedded diagnostics, and access to device information. If you cannot reach the operating system, begin with these built-in tools. Choose the tool that matches the failure before collecting logs.

How do you access HPE iLO 5 and check server health?

Use iLO before rebooting whenever possible because a live view can preserve evidence that disappears after a power cycle. You need the iLO network address and an account with appropriate privileges. Connect through a secured management network rather than exposing the interface directly to the internet.

Connect to iLO 5 and review the System Information dashboard

  1. Open the iLO address in a supported browser and sign in.
  2. Record the server name, serial number, firmware versions, power state, and any active warnings.
  3. Open the System Information pages and note whether the server reports a degraded or failed component.

Check hardware health, fans, temperatures, power supplies, and storage

Review each health category instead of relying only on the overall green or red status. Check fan redundancy, temperature sensors, power input, memory, processors, network adapters, controllers, and physical drives. A warning that is not currently critical can still explain an intermittent incident. This is your primary hardware health monitoring view.

Use the iLO event log and remote console

Open the iLO event log and export or record entries around the failure. Then launch the remote console to observe POST, boot selection, and on-screen hardware messages. Save screenshots when the condition is visible. Confirm that the health page and event timestamps support the same diagnosis, then preserve the evidence before making changes.

How do you collect and interpret the Active Health System Log?

The Active Health System collects telemetry about server hardware, firmware, configuration changes, and selected operational events. It is especially valuable when a fault is intermittent or has already cleared. Treat it as an evidence package, not as a simple list of errors. Look for events that started before the visible symptom and for repeated patterns involving the same component.

Download the Active Health System Log from iLO 5

  1. Sign in to iLO 5 and open the Active Health System or support information area.
  2. Choose the option to download or collect the AHS log.
  3. Save the file with the server name, date, and incident number in the filename.

Choose an appropriate time range for the incident

For a known outage, select a range that begins before the first symptom and ends after recovery. For recurring crashes, include enough history to compare normal and abnormal periods, but avoid collecting an unnecessarily large file. Note the server timezone and whether the clock was accurate.

Review or share the log with HPE Support

Use the log alongside the IML, iLO events, storage reports, and operating-system records. Do not edit the original file. If you open a case with Hewlett Packard Enterprise, provide the original AHS file, the incident timeline, server identifiers, and a short description of what changed. Download the log now and keep an untouched copy before troubleshooting further.

What is the Integrated Management Log, and when should you use it?

The Integrated Management Log is a persistent record of hardware and management events on the server. It can show power transitions, memory problems, temperature conditions, fan failures, storage-controller warnings, and other events that may not appear in an application log. Use it to establish when a condition began and whether it was corrected, repeated, or escalated.

Find IML entries in iLO 5 or UEFI System Utilities

In iLO, open the server information or logs area and select the Integrated Management Log. If remote access is unavailable, restart the server and open UEFI System Utilities during startup, then locate the embedded management or server log options. Export the entries where possible, or photograph the screen if the server is in a recovery state.

Interpret critical, caution, and informational events

Critical entries usually indicate a failed or unavailable component and require immediate investigation. Caution entries may identify a developing issue, such as a corrected memory error or a temperature approaching a limit. Informational entries provide context, including reboots, firmware updates, or component replacement. Read the event details, not only the severity label.

Clear or preserve log entries during troubleshooting

Preserve the IML before clearing it. Clearing can remove useful evidence and should occur only after exporting the record or when a documented procedure requires it. Compare new entries after a repair with the preserved baseline. Export the IML and record the event IDs before resetting anything.

How can you use POST messages and UEFI diagnostics to troubleshoot startup failures?

Startup failures often provide the most direct hardware clues because the server checks components before the operating system loads. Watch the console carefully and record the exact wording, numeric code, slot number, and whether the message appears once or on every boot. Avoid guessing from a short description such as “server will not start.”

Identify POST error messages and diagnostic codes

POST error messages can identify missing memory, processor faults, unsupported configurations, failed fans, boot-device problems, or degraded storage. Use the server documentation or HPE support resources to interpret the code. Confirm whether the message points to a component, a slot, or a configuration mismatch before removing hardware.

Run memory, processor, and system-board checks

From UEFI System Utilities, launch the available System ROM diagnostics or embedded hardware tests. Run the test associated with the suspected component, then record the result and any failure ID. A passing test does not always rule out an intermittent fault, so compare it with iLO, AHS, and IML history.

Review firmware settings and boot configuration

Check boot mode, boot order, secure boot settings, virtualization options, storage-controller mode, and recently changed firmware settings. Do not load defaults without recording the current configuration because that can create a second problem. Correct one setting at a time, save the change, and test whether the same startup message returns. Record the exact code and test result before escalating.

How do you diagnose storage and RAID problems?

Storage incidents can look like operating-system corruption, application timeouts, or sudden server resets. First determine whether the problem is a physical drive, controller, array, logical volume, cable or backplane, or a software path. Do not replace a drive solely because an application reports slow storage. Confirm the hardware state and protect data before making changes.

Open HPE Smart Storage Administrator

Use HPE Smart Storage Administrator (HPE SSA) from Intelligent Provisioning, UEFI tools, a supported operating-system installation, or the installed SSA interface. Select the correct Smart Array controller and capture its configuration, firmware version, cache status, and current alerts before modifying the array.

Check controller, drive, array, and logical-volume status

Review each physical drive for predictive failure, failed status, unusual media errors, and link problems. Then check array consistency, rebuild progress, spare assignment, logical-volume state, and controller cache protection. A rebuilding array may be usable but vulnerable to a second drive failure. Follow the documented replacement procedure and never initialize or delete an array to clear an alert.

Compare storage alerts with iLO and operating-system logs

Match the drive bay, controller name, and timestamp across SSA, iLO, the IML, and Windows Server or Linux logs. A storage-controller event that appears before filesystem errors is stronger evidence than the filesystem error alone. Export the controller report and record the affected bay. Make a repair decision only after confirming the same component across at least two sources.

How should you correlate system logs with Windows or Linux events?

Correlation turns separate alerts into a defensible timeline. Start with the user's symptom, then work backward through operating-system events and server-management records. The goal is to distinguish a failed component from a firmware issue, driver problem, configuration change, or application response to an underlying hardware event.

Match timestamps across iLO, AHS, IML, and operating-system logs

Confirm the timezone, clock accuracy, and daylight-saving settings on iLO, the server, and the operating system. Build a timeline with the first warning, the first service interruption, reboots, recovery actions, and repeated alerts. Allow for small timestamp differences and note whether an event was logged before or after a reboot.

Investigate hardware, firmware, driver, and application symptoms

A corrected memory event followed by a system crash suggests a different path than an application error with no hardware warnings. Compare firmware and driver versions with the supported baseline. HPE OneView can help manage larger fleets, while HPE InfoSight may provide additional infrastructure insight where the service and platform are supported. Use HPE Active Health data to add historical context.

Document findings before replacing components or escalating the case

Write down the symptom, affected component or slot, event IDs, timestamps, tests run, firmware versions, recent changes, and the action you recommend. Attach the original AHS, IML, iLO, SSA, and operating-system exports. This prevents duplicate troubleshooting and gives HPE Support a reproducible case. Make one documented change at a time and verify the result.

Begin with iLO 5 to capture the current health state and event history, then collect the Active Health System Log before clearing or changing anything. For startup and storage faults, use UEFI diagnostics and HPE Smart Storage Administrator, and compare their results with IML and Windows Server or Linux events. A timestamped evidence package is more reliable than a single warning. With that process, you can isolate the likely cause, choose the next safe repair, and approach Hewlett Packard Enterprise Support with useful information.

Can I use iLO 5 if the operating system is not running?

Yes. iLO 5 operates independently of Windows Server or Linux and can show hardware status, logs, remote console output, and power controls when the host operating system is unavailable.

What if the Active Health System Log is too large to review?

Choose a time range that begins before the incident and ends after recovery, then provide the original file to HPE Support. Do not alter the original log; create a separate working copy if you need to filter or annotate it.

Can I clear the Integrated Management Log to remove old warnings?

You can clear it in supported management interfaces, but preserve or export the entries first. Clearing the log before collecting evidence can remove details needed to diagnose an intermittent problem.

What if a storage drive is marked predictive failure but the array is still online?

Capture the controller, drive, array, and logical-volume status immediately, then follow the supported replacement procedure. Avoid removing a drive or initializing the array without confirming the correct bay and recovery plan.

Do I need to run every diagnostic test?

No. Start with the test that matches the symptom, such as memory diagnostics for memory events or storage-controller checks for RAID alerts. Expand testing when results are inconclusive or when the issue is intermittent.

Can operating-system logs identify a failed server component by themselves?

Usually not. Windows or Linux may show the symptom, such as a timeout, filesystem error, or unexpected reboot, but iLO, AHS, IML, UEFI diagnostics, and storage tools usually provide the hardware-specific evidence.