By HPE ProLiant DL360 Gen10 · Published · Updated
You have an HPE ProLiant DL360 Gen10 ready for deployment, but you need to choose the right Microsoft Windows Server edition, prepare installation media, configure the storage controller, and make sure the server boots correctly. A missed firmware update or unconfigured RAID volume can leave Windows Setup unable to see any disk.
This guide explains the complete Windows Server installation process for the DL360 Gen10. You will know how to prepare the hardware, access the server locally or remotely, create storage, complete Setup, install HPE management tools and drivers, and troubleshoot the most common installation failures.
The DL360 Gen10 can be installed locally through a bootable USB drive or remotely through the HPE iLO 5 virtual media and console.
Storage may not appear in Windows Setup until the correct HPE Smart Array controller driver is loaded or the RAID volume is created.
Updating system ROM, iLO firmware, storage-controller firmware, and Windows Server drivers before production use helps prevent installation and hardware-recognition problems.
Confirm the Windows Server release and edition against the HPE support documentation for your server configuration. Standard and Datacenter editions have different licensing and virtualization rights, while Server Core and Desktop Experience suit different administration needs. Plan to use a bootable USB drive, physical optical media if available, or virtual media through HPE iLO 5. For a remote deployment, the iLO license level must support remote console and virtual media features.
Download a legitimate Microsoft Windows Server ISO and create or mount Windows Server installation media. Record the product key, static IP address, subnet mask, gateway, DNS servers, server name, time zone, and a strong local Administrator password. Keep the license information separate from the server if you will activate through a volume licensing service.
Verify installed memory, disks, network adapters, and the Smart Array model. Download the latest compatible Windows Server drivers, system ROM, iLO package, and storage-controller package from HPE. You can also review HPE Active Health System logs for hardware warnings. Decide the installation method now, then gather every required file before taking the server offline.
Connect a monitor and keyboard to the server, or connect to the management network and open HPE iLO 5 in a browser. A licensed OneView or iLO remote console lets you view POST messages, enter firmware menus, and mount an ISO without being physically present. Use a dedicated, reachable management address and change default credentials before production use.
Check the current system ROM, iLO firmware, backplane firmware, and storage-controller firmware. Apply compatible firmware updates using an HPE SPP package, approved online method, or the server's firmware utilities. Read the release notes and maintain power stability while updates run. Reboot and confirm that each update completed successfully.
Enter System Utilities during startup, open Boot Options, and select UEFI boot mode unless your existing deployment specifically requires Legacy BIOS. Put the intended USB device or virtual CD/DVD ahead of the internal drive temporarily, while keeping the RAID logical drive available as a later boot option. Save changes and record them. The immediate decision is whether your organization requires UEFI-only security features such as Secure Boot.
Identify the installed Smart Array storage controller and the disks connected to it. In the controller configuration utility, choose an appropriate RAID configuration: RAID 1 is common for two boot disks, while RAID 5 or RAID 10 may suit larger arrays depending on capacity, performance, and fault-tolerance requirements. Select the correct drives, initialize the array if required, and create one logical drive for the operating system.
Press the indicated key during POST to open Intelligent Provisioning, or enter UEFI System Utilities and open the HPE Smart Array configuration menu. HPE Intelligent Provisioning can guide hardware setup and may offer an assisted operating system installation. Do not erase disks containing data you need. If the controller is in HBA mode, Windows may see individual disks instead of a RAID logical drive.
Check that the array is healthy, the logical drive is online, and the expected capacity is visible. Allow background initialization to complete when practical, especially before production workloads. Save the controller configuration and reboot. You can now proceed when the logical drive appears as an available target and no controller warning is displayed.
Insert the prepared USB drive or mount the ISO through iLO virtual media. Restart the server and open the one-time boot menu, commonly with F11, then select the UEFI entry for the correct device. If you use HPE Intelligent Provisioning, choose the operating system installation workflow and provide the media when requested. Watch the console for the Windows loading screen rather than assuming the server booted from the intended source.
Choose the licensed edition, then select Custom installation for a clean operating system deployment. Server Core reduces the attack surface and resource use, while Desktop Experience provides a graphical interface for administrators who need it. Read the edition name carefully before continuing because changing editions later may require a separate conversion or reinstall.
If Setup reports that no drives are available, choose Load driver and provide the extracted driver package for the HPE Smart Array controller. Use a second USB drive or a folder on the mounted media. Select the driver matching the Windows Server version and architecture. Once the logical drive appears with the expected size, select it and continue rather than creating a second, unintended array.
In the disk selection screen, choose the RAID logical drive you created. For a clean deployment, remove old partitions only after confirming that the disk contains no required data, then select unallocated space and let Windows create the EFI System, Microsoft Reserved, recovery, and operating system partitions. If your organization uses a standard partition layout, follow that documented design instead.
Allow Setup to copy files and restart several times. When prompted, set a long, unique local Administrator password and store it in your approved password manager. After first sign-in, rename the server and configure a static address, DNS, gateway, and preferred time source if the machine will not use DHCP. Do not join a domain until DNS and time synchronization are working.
Unmount the ISO or remove the USB device after Setup finishes, then reboot. Confirm that Windows starts from the RAID logical drive and that the system does not return to Setup. Sign in, open Disk Management, and verify the expected system and data volumes. The installation is complete when the internal drive is the first usable boot target and Windows loads without media attached.
Install the approved HPE Service Pack for ProLiant or the individual packages required for your Windows Server release. Apply the correct Windows Server drivers for the Smart Array controller, network adapters, chipset, and other devices. HPE management utilities can expose hardware health, storage status, and alerts to Windows or HPE OneView. Reboot when a package requires it and verify Device Manager shows no unknown devices.
Set the production network profile, DNS registration, firewall rules, and management VLAN access. Run Windows Update, configure a reliable domain or NTP time source, and confirm the clock is correct. Complete activation and licensing using a valid retail, volume, or organization-managed method. Record the server's IP, firmware levels, and license status in your deployment documentation.
Join the domain if appropriate, then add only the roles and features the workload requires. Apply your baseline policies, disable unnecessary services, configure Microsoft Defender, schedule backups, and restrict administrative access. If HPE OneView manages the server, add it using the approved profile and confirm compliance. Make a fresh system-state or image backup before handing the server to users.
Confirm that the HPE Smart Array controller is detected in UEFI System Utilities and that the logical drive is online. If the array is missing, complete the RAID configuration first. If the array is present but invisible to Setup, load the controller driver that matches your Windows Server build. Also check controller mode, cable connections, disk health, and whether the driver was extracted rather than left inside a compressed package.
Use the one-time boot menu and select the UEFI entry for the USB device or iLO virtual CD/DVD. Recreate the USB from a verified ISO if it is not listed, and check that Secure Boot settings match the media. For remote installation, verify the ISO is mounted in the iLO console and that the virtual media connection remains active. Restore the internal RAID logical drive to the preferred boot order after Setup.
Check physical network links, VLAN settings, and the iLO management port separately from the operating system network. Review Device Manager and install the matching HPE driver packages, then reboot. If hardware still reports errors, inspect HPE Active Health System data and compare firmware versions with HPE guidance. Take one corrective action at a time and confirm the result before moving to the next issue.
A successful DL360 Gen10 deployment depends on two decisions: configure a healthy RAID logical drive before Setup, and use compatible firmware and drivers for the chosen Windows Server release. Whether you install from USB or through iLO virtual media, verify the server boots from its internal drive, then complete updates, networking, activation, security, and backups. Work through each checkpoint methodically, and you will have a stable foundation for your server roles.
Yes. Use the HPE iLO 5 remote console and virtual media to mount a Windows Server ISO and control the installation remotely. Confirm that your iLO license supports these features and that the management network is reliable.
The RAID logical drive may not have been created, the controller may be in an unexpected mode, or Setup may lack the HPE Smart Array driver. Verify the array in UEFI or Intelligent Provisioning, then load the correct driver during Setup.
Create a RAID 1 logical drive with the two disks before installing Windows Server. This mirrors the operating system data, but it is not a substitute for a separate backup.
Yes. Server Core is a supported installation choice when the selected Windows Server edition and workload support it. Choose it during Setup because switching between installation options later may require additional steps or a reinstall.
Remove the USB drive or unmount the iLO virtual media after the first installation phase. Then check the boot order and set the internal RAID logical drive as the primary boot device.
You should compare the system ROM, iLO, storage-controller, and related firmware with HPE's compatibility guidance before production deployment. Updating them early can resolve hardware-recognition and boot problems, but follow release notes and maintain stable power during the process.