How to Create and Modify Storage Arrays on an HPE ProLiant DL360 Gen10

Configure RAID storage safely using HPE tools, UEFI utilities, and remote management workflows

By HPE ProLiant DL360 Gen10 · Published · Updated

You need to create or change storage on an HPE ProLiant DL360 Gen10, but the choices are not limited to selecting a few disks. You must identify the installed controller, confirm drive and backplane compatibility, choose an appropriate RAID layout, and understand how changes may affect existing data. The server may also offer several configuration paths, including local utilities and remote management.

This guide explains how to create and modify storage arrays on an HPE ProLiant DL360 Gen10. You will learn how arrays and logical drives work, how to use HPE Smart Storage Administrator and boot-time tools, how to expand or migrate storage, and how to monitor the result without overlooking backup or compatibility requirements.

Key Takeaways
  • On a DL360 Gen10, an array is built from physical drives, while the operating system typically sees the resulting logical drive.

  • You can configure storage through HPE Smart Storage Administrator, UEFI System Utilities, Intelligent Provisioning, or supported remote-management workflows.

  • Changing RAID levels, expanding arrays, or migrating logical drives can affect performance and carries data-loss risk, so verify backups and controller compatibility first.

What do storage arrays and logical drives do on an HPE ProLiant DL360 Gen10?

Arrays, physical drives, and logical drives explained

An array groups multiple physical drives under an HPE Smart Array controller. The controller presents one or more virtual storage devices to the operating system. Each presented device is a logical drive, also commonly called a logical volume. You can create multiple logical drives from one array, but each one has its own capacity and RAID settings.

How RAID levels affect capacity, redundancy, and performance

A RAID level determines how data and parity are distributed. RAID 0 provides capacity and speed without drive protection. RAID 1 mirrors data and is suitable for two-drive boot volumes. RAID 5 balances capacity and single-drive protection, while RAID 6 tolerates two failed drives. RAID 10 combines mirroring and striping for strong performance, but uses half of the raw capacity in a typical layout.

Check drive, backplane, and controller compatibility first

The server's drive cage, backplane, controller model, and installed media must work together. Confirm whether the chassis uses SAS, SATA, or NVMe devices and whether the bays are hot-plug drive bays. A sound array configuration starts with matching drive types and an approved topology.

Now document the current controller, bays, drive models, and intended RAID level before making changes.

What should you check before creating an array?

Confirm the installed HPE Smart Array controller

Identify the installed HPE Smart Array controller in the server's storage information, UEFI System Utilities, HPE Smart Storage Administrator, or HPE Integrated Lights-Out 5. The controller determines supported RAID levels, maximum drive counts, cache behavior, encryption options, and whether online expansion or migration is available. Do not assume every DL360 Gen10 has the same storage controller.

Review drive health, type, capacity, and firmware

Check each drive's model, interface, capacity, sector format, firmware, and health status. For predictable results, use drives of the same type and capacity within an array. A larger drive can often be used, but the array may only use capacity matching the smallest member. Remove drives reporting errors, predictive failure, or incompatible firmware before configuration.

Back up data and plan for initialization time

Creating a new logical drive can erase selected media. Also plan for drive initialization, which may run in the background and reduce performance. Expansion, migration, and rebuilds can take many hours, especially with large disks. Confirm a tested backup, maintenance window, and recovery plan before proceeding.

Record the controller and drive inventory, verify the backup can be restored, and postpone the change if any component is unsupported.

How do you create a storage array with HPE Smart Storage Administrator?

Launch HPE Smart Storage Administrator

HPE Smart Storage Administrator is the main graphical tool for configuring HPE Smart Array storage. Start it from the operating system if installed, or boot from supported HPE media or a maintenance environment that includes the utility. Version names and menu labels can vary, so use the release that supports your controller and server firmware.

Select the controller and physical drives

  1. Open the storage or controller view and select the HPE Smart Array controller.
  2. Review existing arrays and logical drives before selecting an unconfigured drive group.
  3. Choose the compatible physical drives, checking that their interface, size, sector format, and status match your plan.

Choose a RAID level and create the logical drive

  1. Select the required RAID level based on redundancy, performance, and usable capacity.
  2. Set the logical-drive size, stripe size, caching policy, and other options only when you understand their effect.
  3. Review the summary carefully, accept the warning, and apply the configuration.

The utility may begin initialization immediately or offer a background initialization option. Confirm that the new logical drive appears with the expected size and status before presenting it to the operating system.

Use HPE Smart Storage Administrator to save or record the final configuration, then initialize and format the logical drive through the operating system if required.

How do you create an array through UEFI System Utilities or Intelligent Provisioning?

Open the storage configuration workflow during boot

UEFI System Utilities provides a pre-boot method for configuring storage without relying on an installed operating system. Restart the server and use the on-screen prompt to enter System Utilities. Menu paths differ by firmware version, but storage options are generally found under System Configuration, Storage Options, or an embedded HPE Smart Array controller.

Configure arrays and logical drives in UEFI

  1. Select the controller and open its array or logical-drive configuration screen.
  2. Choose available drives, select a RAID level, and define the logical-drive size.
  3. Review warnings about erasing data, commit the configuration, and wait for confirmation.

Use this route when the operating system is not installed or when you need a basic controller setup before deployment. Avoid changing unrelated boot, firmware, or security settings while working in the utility.

Use Intelligent Provisioning when installing an operating system

Intelligent Provisioning, also known as HPE Intelligent Provisioning, can guide you through controller configuration as part of an operating-system installation. Select the storage controller, create the array and logical drive, then continue to deployment. It may also provide driver and firmware assistance, but available workflows depend on the server firmware and Intelligent Provisioning version.

Choose UEFI for direct pre-boot configuration, or use Intelligent Provisioning when array creation is part of a fresh operating-system deployment.

How do you modify an existing storage array?

Expand an array by adding compatible drives

Online array expansion adds compatible drives to an existing array, increasing its available capacity without immediately deleting the current logical drive. In HPE Smart Storage Administrator, select the array, choose the expansion action, and identify eligible drives. The controller may require drives at least as large as existing members and may restrict expansion by RAID level or enclosure layout.

Migrate a logical drive to another RAID level

Logical drive migration changes the RAID level or sometimes the stripe configuration while retaining data. For example, a supported controller may migrate RAID 1 to RAID 5 after adding a drive. Not every starting and destination RAID combination is supported, and usable capacity may change. Confirm the destination layout, backup, and controller cache or license requirements first.

Change logical-drive settings and review controller limitations

You may be able to adjust size, stripe settings, caching, or acceleration policies. The controller can reject changes when capacity, drive type, firmware, or existing workload conditions do not meet its rules. Never remove a drive or delete an array as a shortcut for modification unless you have intentionally backed up and rebuilt the storage.

Before applying a change, record the current layout, confirm the supported operation, and schedule the expansion or migration during a monitored maintenance window.

How do you monitor and troubleshoot the array after configuration?

Check drive and logical-drive status

Return to HPE Smart Storage Administrator after configuration and check that the controller, array, logical drive, and every drive report a normal or optimal state. Confirm that the operating system sees the expected device size. Review initialization, expansion, rebuild, cache, and predictive-failure messages rather than relying only on the server's boot screen.

Use HPE Integrated Lights-Out 5 and HPE management tools

HPE Integrated Lights-Out 5 can provide remote hardware health, event logs, storage alerts, and console access. Depending on your environment, HPE OneView can centralize server inventory and alerts, while HPE InfoSight can provide supported predictive analytics. These tools complement, rather than replace, controller-level checks.

Respond to failed, predictive-failure, or rebuilding drives

A failed or predictive-failure drive should be identified by bay and replaced with a compatible drive according to HPE guidance. If the array is rebuilding, avoid unnecessary restarts and monitor progress. A degraded array is vulnerable to another failure, so confirm that the replacement is accepted and that the rebuild begins. Keep workloads light if performance is severely affected, but do not interrupt a healthy rebuild without a documented reason.

Check the controller status and event logs now, and document any degraded state, replacement action, and expected rebuild completion.

What mistakes should you avoid when configuring DL360 Gen10 storage?

Mixing incompatible drives or unsupported configurations

Do not combine SAS, SATA, and NVMe drives casually, or assume that similar-looking devices are interchangeable. Mixing drive types, sector formats, capacities, firmware versions, or unsupported backplanes can prevent array creation or create unpredictable behavior. Use the controller and server compatibility guidance from Hewlett Packard Enterprise before purchasing replacement drives.

Deleting an array or logical drive without confirming the data impact

Deletion can make all data on the selected logical drive inaccessible. A configuration screen may show a warning, but it cannot determine whether you still need the data. Confirm the exact controller, array, and logical drive identifiers, verify a restorable backup, and obtain approval before destructive actions.

Interrupting initialization, expansion, or rebuild operations

Power loss, forced resets, or drive removal during drive initialization, expansion, migration, or rebuild can prolong recovery and may cause data loss. Use reliable power protection, keep the server accessible through iLO, and monitor progress until the operation completes. Do not remove a drive simply because the interface reports slow progress.

Before clicking Apply, compare the proposed change with your documented layout, backup, compatibility check, and maintenance plan.

Successful DL360 Gen10 storage work depends on two decisions: select a supported controller and drive layout, then choose a RAID level that matches your capacity, redundancy, and performance needs. Use HPE Smart Storage Administrator for detailed changes, or UEFI and Intelligent Provisioning during boot or deployment. Back up first, verify every warning, and monitor initialization, expansion, migration, and rebuild activity until the array returns to a normal state. With that process, you can make controlled storage changes confidently.

Can I create an array without an operating system installed?

Yes. Use UEFI System Utilities or a supported HPE Smart Storage Administrator boot environment to configure the controller before installing an operating system. Intelligent Provisioning can also combine storage configuration with a new operating-system deployment.

What RAID level should I use on an HPE ProLiant DL360 Gen10?

Use RAID 1 for a simple two-drive mirrored boot volume, RAID 5 or RAID 6 when capacity and redundancy must be balanced, and RAID 10 when performance and fault tolerance are more important than usable capacity. Confirm that the installed controller supports your selected level.

Can I expand an array without deleting the logical drive?

Often, yes. Supported HPE Smart Array controllers may provide online array expansion, but the operation depends on the controller, RAID level, drive compatibility, and firmware. Verify a backup and confirm the exact supported workflow before applying it.

What if the new drive is not available for expansion?

Check that the drive is unassigned, healthy, compatible with the controller and backplane, and at least as large as required. Differences in interface, sector format, firmware, or encryption state can make a drive ineligible.

Can I migrate a logical drive from RAID 1 to RAID 5?

Some HPE Smart Array controllers support that migration after an additional compatible drive is installed. The option may be unavailable because of controller limitations, insufficient capacity, firmware requirements, or an unsupported starting layout.

What should I do if a drive reports predictive failure?

Record the affected bay and controller message, verify that a current backup exists, and replace the drive with a supported equivalent according to HPE guidance. Monitor the rebuild and confirm that the array returns to an optimal state.